Quantcast
Channel: Symantec Connect - Storage and Clustering - Discussions
Viewing all articles
Browse latest Browse all 543

vxvm:vxconfigd: [ID 702911 daemon.warning] V-5-1-579 Disk group disk_gp: Errors in some configuration copies:

$
0
0
I need a solution

Hi ,

Hardware : Hp blade Gen8 .

VCS : 2 node cluster

Application Resources from one node are switched over to other node automatically and when i switched back to original node its failing .

I can see the below error messages in /var/adm/messages.

an 20 07:24:56 atrcxb3213 last message repeated 10745 times
Jan 20 07:24:56 atrcxb3213 vxvm:vxconfigd: [ID 702911 daemon.notice] V-5-1-768 Offlining config copy 1 on disk c0t0d26s2:
Jan 20 07:24:56 atrcxb3213 vxvm:vxconfigd: [ID 702911 daemon.notice]    Reason: Disk write failure
Jan 20 07:24:56 atrcxb3213 vxvm:vxconfigd: [ID 702911 daemon.warning] V-5-1-579 Disk group ossdg: Errors in some configuration copies:
Jan 20 07:24:56 atrcxb3213 vxvm:vxconfigd: [ID 702911 daemon.warning]   Disk c0t0d26s2, copy 1: Block 0: Disk write failure
Jan 20 07:24:56 atrcxb3213 vxvm:vxconfigd: [ID 702911 daemon.notice] V-5-1-0 Disk group import of ossdg succeeded.
Jan 20 07:24:58 atrcxb3213 scsi: [ID 107833 kern.warning] WARNING: /pci@0,0/pci8086,3c04@2/pci103c,338e@0,1/fp@0,0/disk@w5006016e46e011d3,1a (sd4):
Jan 20 07:24:58 atrcxb3213      SCSI transport failed: reason 'timeout': giving up
Jan 20 07:24:58 atrcxb3213 vxdmp: [ID 443116 kern.notice] NOTICE: VxVM vxdmp V-5-0-0 i/o error occured (errno=0x6) on dmpnode 264/0x103
Jan 20 07:24:58 atrcxb3213 last message repeated 4 times
Jan 20 07:24:58 atrcxb3213 vxio: [ID 262433 kern.warning] WARNING: VxVM vxio V-5-3-1143 voldiosiodone_fun: Hung io returned; disk = c0t0d26s2, hung
 ios remaining 4
Jan 20 07:24:58 atrcxb3213 vxio: [ID 262433 kern.warning] WARNING: VxVM vxio V-5-3-1143 voldiosiodone_fun: Hung io returned; disk = c0t0d26s2, hung
 ios remaining 3
Jan 20 07:24:58 atrcxb3213 vxio: [ID 262433 kern.warning] WARNING: VxVM vxio V-5-3-1143 voldiosiodone_fun: Hung io returned; disk = c0t0d26s2, hung
 ios remaining 2

Jan 20 07:23:27 atrcxb3213 vxdmp: [ID 447055 kern.notice] NOTICE: VxVM vxdmp V-5-0-0 failover initiated for 264/0x100
Jan 20 07:23:27 atrcxb3213 vxdmp: [ID 447055 kern.notice] NOTICE: VxVM vxdmp V-5-0-0 curpri set to secondary for 264/0x100
Jan 20 07:23:52 atrcxb3213 AgentFramework[6534]: [ID 702911 daemon.notice] VCS ERROR V-16-2-13027 Thread(13) Resource(sybasedg) - monitor procedure
 did not complete within the expected time.
Jan 20 07:23:52 atrcxb3213 Had[6465]: [ID 702911 daemon.notice] VCS ERROR V-16-2-13027 (atrcxb3213) Resource(sybasedg) - monitor procedure did not
complete within the expected time.
Jan 20 07:23:58 atrcxb3213 scsi: [ID 107833 kern.warning] WARNING: /pci@0,0/pci8086,3c04@2/pci103c,338e@0,1/fp@0,0/disk@w5006016e46e011d3,1a (sd4):
Jan 20 07:23:58 atrcxb3213      Error for Command: write(10)               Error Level: Retryable
Jan 20 07:23:58 atrcxb3213 scsi: [ID 107833 kern.notice]        Requested Block: 143404                    Error Block: 143404
Jan 20 07:23:58 atrcxb3213 scsi: [ID 107833 kern.notice]        Vendor: DGC                                Serial Number: 1A0000D980CL
Jan 20 07:23:58 atrcxb3213 scsi: [ID 107833 kern.notice]        Sense Key: Unit_Attention
Jan 20 07:23:58 atrcxb3213 scsi: [ID 107833 kern.notice]        ASC: 0x2a (asymmetric access state changed), ASCQ: 0x6, FRU: 0x0
Jan 20 07:24:42 atrcxb3213 AgentFramework[6530]: [ID 702911 daemon.notice] VCS ERROR V-16-2-13027 Thread(1888) Resource(add_swap) - monitor procedu
re did not complete within the expected time.

Regards ,